Emergency Lighting Checks for Dorset Businesses: What the Law Asks and What the Tests Involve

Most of the time nobody thinks about the small emergency lights over the fire exits and along the corridors. They only matter on the day the power goes off and people need to find their way out. That is exactly why they need checking. A fitting that looks fine on the ceiling can have a battery that no longer holds its charge.

We look after emergency lighting for offices, shops, hospitality venues and industrial units across Poole, Bournemouth, Ferndown and the rest of Dorset. This guide sets out what the law asks of you, what the routine checks involve and where a qualified electrician comes in.

What the law asks of a business

In England and Wales the main rules sit in the Regulatory Reform (Fire Safety) Order 2005. Article 14 says that, where necessary, emergency routes and exits needing illumination “must be provided with emergency lighting of adequate intensity” if the normal lighting fails. Article 17 then says that equipment provided for fire safety must be kept “in efficient working order and in good repair”.

The duty falls on the “responsible person”. In a workplace that is the employer, and also anyone else who controls part of the premises, such as the owner or occupier. In a shared building, the landlord, managing agent and each tenant may all have a part to play, and the government guidance says they should co-operate and co-ordinate with each other.

Your fire risk assessment is where you decide what emergency lighting the premises need. Larger or more complex buildings will usually need a full automatic system. The installation and testing of those systems is normally carried out to BS 5266, the British Standard for emergency lighting.

The routine checks

The government’s fire safety guidance for offices and shops sets out a simple pattern of checks. Some of it you or a nominated member of staff can do yourselves. The rest needs a competent person.

Regular visual checks

Walk the escape routes and look at the fittings. Are they all there, undamaged and showing their charging indicator where they have one? A broken diffuser, a missing exit sign or a light that has been painted over all need reporting.

Monthly test

Once a month, each emergency light should be tested to check it switches on and lights up when the mains supply is cut, following the manufacturer’s instructions. This is usually done with a test key switch fitted for the purpose. Do it at a time when the building is not about to be used in the dark, because the batteries need time to recharge afterwards.

Annual inspection and test

Once a year the system should be tested and maintained by a competent person. This includes running the lights on battery for their full rated duration, checking they stay lit to the end, and inspecting the fittings, signs and wiring. Any failed batteries, lamps or units are replaced, and the results are written up on a certificate.

Keep a log book

Record every test, fault and repair. If a fire officer or your insurer asks to see your emergency lighting records, the log book is what they will want. It also shows you which fittings keep failing.

Common faults to look out for

  • Batteries that pass a quick test but die well before the end of the full duration test.
  • Fittings left off after a refit or a change of tenant, so part of an escape route has no cover.
  • Test key switches that have gone missing, so nobody has been doing the monthly checks.
  • Exit signs pointing the wrong way after an office layout has changed.
  • Old fittings where spare parts are no longer available and a replacement is the sensible option.

Where we fit in

Please leave the wiring itself to a qualified electrician. Changing fittings, adding new escape lighting or fixing a faulty circuit is work on the fixed installation, and it should be done and certified properly.

Our NAPIT-registered team carries out emergency lighting installation and testing for Dorset businesses, from a single shop unit to multi-floor offices and industrial sites. The annual test can be done on the same visit as an EICR for business premises, which keeps disruption to your site down. If you would rather not have to remember any of it, emergency lighting can be built into a planned maintenance contract so the visits come round automatically and the paperwork is kept in one place.

Emergency lighting often sits alongside the fire alarm, and we can look at both together. Our fire alarm installation and testing page has more on that side.

Get your emergency lighting checked

If your emergency lights have not had an annual test in the last year, or you are not sure what your building needs, talk to us. We cover Poole, Bournemouth, Christchurch, Ferndown, Wimborne and the surrounding area. See our commercial electrician services in Dorset or get in touch for a quote.